Description
TruCorp’s AirSim Advance Bronchi X, Airway Management Trainer, can be adjusted to allow for different training scenarios. This design, and the quick set up, means that it’s suitable for use with both beginner and experienced trainees.
The Advance Bronchi X model has visually accurate airways and anatomically correct bronchi to the fourth generation, giving realistic user feedback during airway management and diagnostic procedures.
This true-to-life experience helps trainees become familiar with the physical requirements of intubation and ventilation techniques. With the additional bronchioles, users can train in lung suction, and lung isolation techniques, including, bronchial blocker insertion, single and double endobronchial tubes, and specialized stents.
WHAT PROCEDURES CAN YOU PERFORM ON THE AIRSIM ADVANCE BRONCHI X?
- Diagnostic bronchoscopy
- Lung isolation & suction techniques
- Endotracheal tube insertion
- Double naso-tracheal intubation
- NG tube insertion (Nasogastric tube insertion)
- Combi tube insertion
- Awake fiber opitc intubation
- Bag valve mask ventilation techniques (BVM ventilation techniques)
- Direct laryngoscopy
- Video laryngoscopy
- Awake fiber optic examination
Designed with accuracy in mind, TruCorp airway simulators are the most realistic airway trainers on the market.
Features:
Overview
- Accurate internal anatomy to fourth generation bronchi
- AirSim Airway and nasal cavity designed using CT DICOM data from an adult male
- Delivered in a durable case for transport and storage
Realism
- Visually accurate, with detailed anatomy down to the 4th generation bronchi
- Inflatable tongue allows for life-like replication of tongue edema
Versatility
- Airway tested for over 20,000 intubation cycles, backed by a 5-year warranty
- Modular design allows all parts to be easily replaced
- Included adhesive pads and suction cups can be attached for greater stability
Cleaning
- Thoroughly clean the airway with warm, soapy water or mild detergent, until foreign matter and residue is removed
- As a further step to fully sanitise the product, use an alcohol spray (75%+) and wipe off (This can be performed on both the silicone and latex parts of the manikin)
Safety
- Components inside this trainer contain latex
- Ensure use of protective gloves when handling the latex airway
- Spray lubricant on the airway and equipment prior to use, to aid the procedure and reduce risk of damage to the material
- Do not use strong detergents or enzymatic cleaning agents on this trainer, such as, germicides, disinfectants, chemical agents, ethylene oxide, phenol-based or iodine containing cleaners
Anatomy
- Adult male head and neck created from DICOM CT scan data
- Anatomically accurate airway, including bronchi to the fourth generation
- Lung and stomach bags
Skills Gained:
- Diagnostic bronchoscopy
- Awake fiber optic examination
- Direct and video laryngoscopy
- Endotracheal tube insertion
- Double nasotracheal intubation techniques
- Awake fiber optic intubation
- Full range of supraglottic airway device insertion including combi tube (esophageal tracheal double-lumen airway)
- Lung suction & isolation techniques, including using left and right endobronchial tubes and bronchial blockers
- Single & double endobronchial tubes & specialized stents
- Bag valve mask (BVM) ventilation